ADR 0054: Heaters are read back over the private register protocol

Status: Accepted, amended 2026-10 (see Amendment) · Recorded: 2026-10

Context

ADR 0033 gave heating a write-only send path: a CMD_WRITE_PRIVATE (0x20) frame, an acknowledgement (0x21) as the only feedback, and an entity that showed what it had last sent. That premise held while the registers were known only as writes.

An Atlantic AGILIA IO radiator (node type 52, subtype 1; issue #165) is expected to answer a register read (0C 60 01 <reg>) with the same 0x21 command, echoing the header followed by the value. The write acknowledgement in corpus atlantic_agilia_exchange_setpoint_and_off_read_back has that shape, and the public example lines of the register protocol show reads as 0c60 <reg> <value>. The registers an entity needs are expected to be readable: the room temperature (0x0115, signed hundredths of a degree, raw -1 for a sensor fault), the comfort setpoint (0x0103), the operating mode (0x0100), the regulator state (0x0117: none, standby, heating) and the heater's own maximum setpoint (0x0102). The window sensor (0x010E) is read-only; the register that switches open-window detection on and off is 0x0106. With reads available, a card that shows only the last command is less than the device offers, and a setpoint the heater clamps would show a value that was never held.

Decision

  1. One register table. proto_heating describes every register once: its access (read-only, read/write, write-only) and its value encoding. The same row builds the get payload, the set payload and the decoder of the reply. A write to a read-only register is refused by the codec, so the window sensor cannot be written.
  2. One exchange helper, two operations. send_heating_command() writes (or reads, for a read-only register the heating_control action runs) and read_heating_register() reads and decodes. Both frame a payload and hand it to one private exchange helper, which keeps the outcome bookkeeping ADR 0033 required: link health, exchange counters, error result codes.
  3. State is observed. A decoded reply is stored in IoDevice::heating and the entity callbacks run; the climate entity publishes from there. Nothing predicts a value: the entity keeps showing the last commanded mode and setpoint only until the first read succeeds, and shows neither current temperature nor action before then. The presence preset (0x0110) is write-only, so it stays last-commanded. ADR 0030's overlay stays out of heating: a prediction that is never made needs no withdrawal.
  4. The hub polls the heater. A climate entity gets a status poll, default every five minutes (status_poll_interval, at least 60 s), plus one poll shortly after boot. A poll reads the registers of the heater's profile (ADR 0055) — room temperature, setpoint, mode, regulator state and window sensor — stopping at the first failure, and the maximum setpoint and the detection setting until each has been read once. A failed poll moves its retry onto the StatusPollPolicy backoff ladder, and the regular cadence continues either way.
  5. A write is confirmed by a read. After an accepted mode or setpoint write the entity reads that register back and shows the heater's answer, so a setpoint the heater clamped shows as clamped.
  6. The window function is the detection setting. set_window wrote the read-only sensor register and is gone. set_open_window_detection (on | off) writes 0x0106, and window_open reads the sensor into the action's result message.

ADR 0033's send-path decision (a plain send_and_receive_() on the command channel, the capability predicate gating every entry point, no use of execute_request_and_update_()) stands.

Considered

  • Keep publishing the commanded value and poll separately for a second set of sensors. Rejected: two sources for one value disagree the first time the heater clamps or the user turns the dial; the card must show one.
  • Predict the setpoint and withdraw it on a failed read-back. Rejected: a heater that does not answer reads is exactly the case where the prediction would be wrong and stay on screen.
  • Poll at the cover cadence. Rejected: a heater's state moves over minutes, and each poll costs one exchange per register.

Consequences

  • The reply shape of a read (header echo followed by the value) is confirmed in the corpus only for the write acknowledgement; it is unconfirmed on real hardware until a capture arrives. A reply that does not decode is logged at DEBUG and the poll counts as failed.
  • A climate entity bound without io_device_type: polls with the generic status request until discovery resolves the type, as the other platforms do.
  • The meanings of 0x0117, 0x0106 and 0x010E, and the hundredths encoding of 0x0115, are experimental until a capture or issue #165 confirms them.
  • A background poll uses the scheduled-poll try band (the retry ladder is its retry); a read the user waits on, such as the read-back of a write, keeps the full retry budget.
  • The regular-cadence timer has its own per-device id, so a poll that a linked remote triggers cannot cancel it.
  • Every poll spends radio time on a device that may be silent; the failure ladder bounds it, and status_poll_interval lets a user lengthen it.

Amendment: the setpoint heater offers no presence preset

Recorded: 2026-10. Issue #165: an Atlantic AGILIA IO radiator (type 52, subtype 1). The radiator acknowledged the presence write (register 0x0110) in two field tests and showed no effect: with the room empty all day and the radiator already stepped down, "home" did not bring comfort back. A preset that does nothing visible is worse than none, so point 3's last-commanded presence preset does not exist: the setpoint heater offers no home / away preset, and every preset on the card is one a register reports back. Register 0x0110 stays reachable through the set_presence setting of the heating action.

The two automatic modes (AUTO and PROG) both show as HVAC auto, which leaves the card with no way to switch between them. The profile offers them as the custom presets Auto and Program; each writes the mode register and is confirmed by the read-back like any other mode write.