ADR 0056: Exterior heating is a fan entity

Status: Accepted ยท Recorded: 2026-10

Context

Exterior heating (node type 21: terrace and patio heaters) is a heater that has no setpoint and no measured temperature. The VELUX KLF 200 API specification (Table 277 and the actuator type table, type 21) defines its main parameter as a heat level: 0x0000 is 100 % heat and 0xC800 is 0 %, the position scale a cover or a dimmable light uses with the direction inverted. Subtype 58 takes the main parameter only and is on/off. The type table classified it as a climate device without a platform, so no entity could drive it, and widening the climate gate to it would have sent the private register protocol to a device that takes a position.

Home Assistant offers four entity shapes that could carry "on, with a 0-100 % level": light, switch, fan and climate.

Decision

  1. A fan entity. Exterior heating is a fan: with a 100-step speed that is the heat level; subtype 58 advertises no speed. The type table gives the type its own capability class, HEATER_LEVEL, with the platform name fan, so the climate gate (a heating profile exists, ADR 0055) cannot reach it and the fan platform rejects every other family.
  2. The dimmable light's mapping. Heat p % is the IO position 100 - p, computed with the same round_percent() helper the light uses, and sent as a main-parameter-only execute for every exterior heater (21/0 and 21/58 alike). The first functional parameter of exterior heating is not a cover's, a guessed block is what issue #163 showed to cost a refusal (PARAMETER_UNKNOWN), and an execute without functional parameters is valid on any device. The hub gets set_fan_position() / queue_set_fan_position() with their own queue operation and class guard.
  3. Status read with the ordinary status request. The reply's current position is decoded by the light's decoder into the existing position field; the fan shows 100 - position.
  4. No motion. An exterior heater never moves, so a status reply is always treated as at rest (device_has_no_motion(), shared with the heating-level climate heaters). A command leaves exactly one follow-up poll, and a "moving" flags byte cannot start a series.
  5. No restored state. The fan never restores a saved state at boot: a restored command would be sent to the heater, and the first status poll is the truth.

Considered

  • A light. Rejected: Home Assistant shows a brightness slider and light services for a heater.
  • A switch. Rejected: it has no level.
  • A climate entity. Rejected: the device has no setpoint, and a climate card would show a temperature control that does nothing (the cost the plain electrical heater already pays).
  • A number entity beside a switch. Rejected: two entities for one device, and the level and the state could disagree.

Consequences

  • Exterior heating is experimental: no heater has been exercised on hardware. The mapping and the status read rest on the public specification and stay unconfirmed until a capture or a reporter's heater confirms them.
  • A change made at the heater itself shows after the next command or reboot: there is no periodic poll at rest, as for a cover.
  • Turning on without a level uses the last level the entity saw, which is lost at reboot; the first turn-on after a boot is full heat.
  • The fan platform needs a host stub of ESPHome's fan component, checked by make stub-sync.