Sending opcodes this project has not fully decoded yet, to learn what a device answers. This is a deliberately gated feature. Every probe but two is read-only reconnaissance; the exceptions, subscribe_event and unsubscribe_event, change the device and are marked as such below. read_object reads a device object in several frames and is described in Reading a device object. register_00 and register_01 read one register and are described in Reading registers.

Warning
Sends opcodes this project has not decoded — use with caution. A probe's reply format is, by definition, not yet understood. Sending one to a real device is normally low-risk (most of these are read-shaped requests real hubs send routinely), but it is not risk-free: an unknown command could have effects on the target device that this project cannot predict. Probes only ever reach devices already paired to this hub (see below). Prefer the field-observed starting values given below over inventing your own, and prefer testing on a light/switch over a motor when you do widen — see "Widen carefully" below.
subscribe_event writes a subscription into the device, and no confirmed way to remove it is known. unsubscribe_event is an untested attempt at one. A battery-powered device may spend battery on the reports it then sends. Use it on one device and one event at a time, start with index 1, and read the table rows below before you run it.

home_io_control.diagnostic_probes: true enables two Home Assistant actions, probe_device and probe_sweep, for sending a handful of opcodes this project has observed on the wire but never fully decoded, and for reading back the raw, uninterpreted reply. This is protocol-research tooling for closing exactly that kind of open question on hardware you own — see ADR 0024 for how it is gated and isolated from the rest of this component, and ADR 0060 for the one probe that changes a device.

home_io_control:
  node_id: "C0FFEE"
  system_key: "..."
  diagnostic_probes: true

It only ever targets a device already paired to this hub. probe_device/probe_sweep resolve their target the same way every other management action does — there is no path from this instrumentation to a device this hub has not already paired with and does not already hold a key for. Every probe additionally refuses while the target device's last known state is "moving" — an unknown frame is never sent into a device state machine that is already mid-transaction. This is the device's last reported movement state, not a check on anything in flight: it never applies to a light/switch, and it can be stale if the device was last moved from a physical remote the hub never saw.

Calling the actions

Same node-scoped naming as every other action in this component — see Home Assistant actions for the full explanation of how <node_name> is derived from esphome.name. For a config with name: hioc-heltec-v2:

action: esphome.hioc_heltec_v2_probe_device
data:
  device_id: "FEEB1E"
  probe: "private2"
  index: "0x09"

To read FP10, FP15 and FP16 of a water heater, pass the FPI2 bitmap to status_fp_high as the index:

action: esphome.hioc_heltec_v2_probe_device
data:
  device_id: "FEEB1E"
  probe: "status_fp_high"
  index: "0x43"

probe_sweep takes a range instead of a single index:

action: esphome.hioc_heltec_v2_probe_sweep
data:
  device_id: "FEEB1E"
  probe: "status_ext"
  first_index: "0x00"
  last_index: "0x01"
  • device_id (required, both actions): the 6-hex-character IO-homecontrol device ID, same as every other management action.
  • probe (required, both actions): which frame to send — see the table below.
  • index (probe_device) / first_index + last_index (probe_sweep): always plain strings — "6" and "0x06" are both accepted; anything else is rejected with a clear error rather than silently defaulting to 0. Home Assistant requires every field of an action, so pass index: "0" to a probe that takes no index (get_info1, get_info2, general_info3, status_mp_fp): the hub ignores the value. probe_sweep is bounded to 16 indices per call, spaced a second apart, and reports one line per index (answered / error-coded / silent / refused).
  • Every reply is reported as raw hex plus its command byte, deliberately uninterpreted, because the point of a probe is that the reply's meaning is not yet known. The one exception is a limitation reply (0x26): the message adds a decoded line labelled assumed layout beside the raw hex. probe_device puts it in the result event's response_cmd/response_cmd_name/response_hex fields; a sweep's per-index replies are inline in message — see Home Assistant actions. Every successful reply is also logged at the io_capture DEBUG tag (the same structured logging every other received frame uses), so with logger: level: DEBUG a captured reply pastes directly into scripts/corpus/ingest.py with no reformatting — this does not require the -DIOHOME_FRAME_LOG build flag.

Available probes

probe Sends index selects Start with Evidence for the starting values
private_fn CMD_PRIVATE (0x03) with a chosen function ID The function ID 0x06 or 0x09 Not field-observed on the wire — every captured CMD_PRIVATE frame uses function ID 0x03. On real hardware (17 solar devices plus this project's own mains motors) 0x06 and 0x09 returned a stored/target position: 0x06 is always 00 00; 0x09 tracked shutters closing. Not a battery probe.
private_fn_sub CMD_PRIVATE (0x03) at function ID 0x09, with a chosen second payload byte The second payload byte (data[1]) 0x01 Not field-observed. Every CMD_PRIVATE frame ever captured — by this project or by a real hub — has 0x00 in this byte, so nothing on air pins down what it means. Treat any reply as uninterpreted.
status_ext Extended CMD_PRIVATE at selector 0x80 The block/N value 0x00 and 0x01 Field-observed: real hubs send exactly these two values to real motors.
status_ext_fn6 Extended CMD_PRIVATE at selector 0x80, function ID 0x06 The block/N value 0x00, then 0x80 The 4-byte extended shape is field-observed: a real hub sends 03 80 00 00 and 03 80 01 00 to real motors (40 frames across two logs), and the 0x80 at data[1] is what makes the 0x04 reply carry its trailing extended block. The function ID 0x06 in that shape is not field-observed — no hub has ever been seen sending it. probe_sweep caps a run at 16 consecutive indices, so 0x80 is out of reach of a sweep starting at 0 — send it with probe_device (or sweep 0x80–0x8F explicitly).
status_ext_fn9 Extended CMD_PRIVATE at selector 0x80, function ID 0x09 The block/N value 0x00, then 0x01 Same shape evidence as status_ext_fn6; the function ID 0x09 in this shape is not field-observed. On the ordinary 3-byte form, 0x09 returned a stored position on every device tested — not a battery value.
get_info1 CMD_GET_INFO1 (0x54), no payload — (probe_device only; probe_sweep rejects it) — Field-observed: a real hub sends 0x54 on air. Two 0x55 answers are in the corpus (velux_window_probe_metadata_replies, somfy_rs100_probe_get_info1_sx1262); their layout is not decoded. A device may also draw an 0xFE "opcode not supported" or nothing at all — that is itself a result worth recording.
get_info2 CMD_GET_INFO2 (0x56), no payload — (probe_device only; probe_sweep rejects it) — The request has never been captured; it rests on the protocol's even=request / odd=answer pairing rule. The answer 0x57 is captured and carries a leading ASCII reference string followed by the packed type/subtype bytes this component already decodes. Reply strings are wire-observable and citable as-is; do not attempt to resolve one to a model name from any non-public source.
general_info3 CMD_GET_GENERAL_INFO3 (0x58), no payload — (probe_device only; probe_sweep rejects it) — —
private2 CMD_PRIVATE2 (0x0C), long wire form The modifier byte 0x06, then 0x05, 0x09 Field-observed: a real hub sends exactly these modifier bytes in the long form to real motors (e.g. request data D4 00 80 D8 06 00). On the Sunea awning and the Izymo dimmer the long form at modifier 0x00 or 0x03 draws only D4 00 in place of a value, also after a My change; use private2_short to read a stored favourite.
private2_short CMD_PRIVATE2 (0x0C), short wire form Same as private2 0x03, then 0x09 Field-observed: a real hub sends the short form with these modifiers (e.g. request data D8 03 00 00). Index 0x00 (request D8 00 00 00) read the stored favourite position of a Somfy Sunea awning: the reply's main value followed the My position saved with the remote (see "Reading a `private2` / `private2_short` reply" below). Experimental on any other device.
status_mp_fp CMD_PRIVATE (0x03) function 0x01, FPI mask 0xFE (main parameter plus FP1-FP7), no index — (probe_device only; probe_sweep rejects it) — The same read-only status request a VELUX KLF 200 gateway sends to its devices (public KLF 200 API specification v3.18, section 10.3.1.4), heard on air at 868 MHz and 2.4 GHz. This is the gateway's position and status poll: it does not read a limitation, so it cannot show rain protection (use limitation for that). The probe reports the reply raw: flags 2D, the main parameter, then the parameter values. The water heater poll sends the same read and takes the main parameter as the target temperature (corpus atlantic_calypso_probe_status_mp_fp).
status_fp_high CMD_PRIVATE (0x03) function 0x01, FPI1 0x00 (main parameter only), FPI2 set to the index, one status type per set bit The FPI2 bitmap, 0x01 to 0xFF with at most 7 bits set: bit 7 = FP9 down to bit 0 = FP16 (0x43 reads FP10, FP15 and FP16; 0x78 reads FP10 to FP13; any other value is rejected; probe_sweep refuses this probe because the index is a bitmap) 0x43 The status_mp_fp request with the second parameter bitmap of the KLF 200 API specification v3.18, section 10.3.1.4. A device that does not know it may answer 0xFE or stay silent. Answered on air: an Atlantic Adelis towel dryer answers index 0x78 with FP10 to FP13 (issue #202, corpus atlantic_adelis_probe_status_mp_fp). In the towel dryer's reply FP12 is the comfort setpoint and FP13 the eco setback, each a big-endian value scaled over a range like a temperature main parameter (FP12 0x770C = 19.5 °C over 7–28 °C, FP13 0x2ADB = 3.5 K over 2–9 K), equal to the dryer's own registers 0x0103 and 0x0104. An Atlantic Calypso Connecté water heater answers index 0x43 with FP10, FP15 and FP16, unauthenticated; its main parameter is the target temperature, as in its status_mp_fp reply (issue #198). The probe reports the reply raw: flags, the main parameter, the FPI2 echo, then one 16-bit value per set bit; nothing decodes it.
limitation CMD_LIMITATION_STATUS_REQ (0x25) with data {selector, 00, 00} 0 = resulting minimum, 1 = resulting maximum (any other value is rejected; probe_sweep accepts 0 to 1) 0, then 1 The request pair a VELUX KLF 200 gateway sends to its windows every five minutes, heard on air at 868 MHz in issue #98 (selector 80, then C0). Its purpose follows the KLF 200 API specification v3.18, section 10.5 (get limitation: resulting minimum and maximum). The value layout is confirmed on a VELUX window dry and under rain; the originator and remaining-time bytes are unverified.
subscribe_event CMD_SUBSCRIBE_EVENT (0x73) with data 01 <event hi> <event lo> 0 = battery level event 0x2001, 1 = local sensor event 0x2005 (any other value is rejected; probe_sweep refuses this probe) 1 Both indexes accepted by an RS100 Solar io (issue #156). The one probe that changes a device: it asks the device to report the event from now on, and no way to cancel that is known. Only those two events can be sent. A try the device authenticated but did not answer is sent once more, never a third time, so a device that takes the subscription and says nothing back ends as "accepted but no response". The RS100 answers at once with the event's current value, which the probe result names ([event 0x2005, 5 data bytes]) and puts on the "Last Device Event" sensor. To read these values regularly, use the cover keys sun_level_poll_interval and battery_level_poll_interval instead (Sun level and battery level).
unsubscribe_event CMD_SUBSCRIBE_EVENT (0x73) with data 00 <event hi> <event lo> Same as subscribe_event (probe_sweep refuses it too) 1 Untested guess. The subscribe request with its first byte cleared, as an attempt to undo a subscription. Whether it works shows only in whether the device's reports stop on "Last Device Event" afterwards; an answer to the request alone proves nothing. Same guards and re-send rule as subscribe_event.
read_object CMD_TRANSFER_OPEN (0x46), then CMD_UNKNOWN4A_REQ (0x4A) blocks, then a close 0 to 29, one object each, listed in Objects you can read (any other value is rejected; probe_sweep refuses this probe) 2 first, then 3, 4, 0, 1 Reads, never writes. See Reading a device object.
register_00 CMD_WRITE_PRIVATE (0x20) with data 0C 60 00 <index>: a read of register 0x00<index> The low byte of the register number, 0 to 255 0, then upward in blocks of 16 (probe_sweep accepts it) Swept on an Atlantic Calypso Connecté water heater (issue #198). Only for register-protocol heaters and domestic hot water devices; refused for every other kind. Read direction only: see Reading registers.
register_01 CMD_WRITE_PRIVATE (0x20) with data 0C 60 01 <index>: a read of register 0x01<index> The low byte of the register number, 0 to 255 0, then upward in blocks of 16 (probe_sweep accepts it) The request shape climate support sends to Atlantic AGILIA IO radiators when it polls them (issue #165). Same kind restriction and read-only guarantee as register_00.

A get_info2 reply (0x57) leads with printable ASCII: paste the raw hex into the corpus and read the string off it, but record only what the wire shows — do not resolve it to a model name from any non-public source.

What each probe and index has returned

A running record of what these frames actually draw back — as much as is understood so far.

probe / index what came back
private_fn fn 0x06 data[2..3] = 00 00 on every device probed — two mains motors of ours plus 17 solar shutters via a field reporter. No content.
private_fn fn 0x09 data[2..3] = a stored position: D8 0A on the dimmer (0xD8 == POS_FAVORITE), 58 22 on the awning; solar shutters in the field data tracked their real position as they closed.
status_ext (fn 0x03), index = block Field-observed selector. Device-dependent framing (see status_ext_fn9). Blocks 0x00/0x01 are what real hubs send.
status_ext_fn9, index = block Reply framing is device-dependent: some devices answer data[0] = the 0x04/0x05 stopped-flag byte with an 0x80-tagged block, others answer data[0] = 0x2D with no block. On the dimmer the 0x80 block tail changes with the index (… 80 00 00 00 at 0x00 → … 80 D8 06 00 at 0x01) — first time one of our own probes drew a non-empty, index-selected block; content is position family (D8 06). The awning ignores the index. A Velux window kept data[2..3] = its live position and appended an index-selected 0x80 tail (78 00 / 50 00 / C8 00 at different blocks — position-family values, meaning undecoded).
status_ext_fn6, index = block data[2..3] zeroed, same as private_fn fn 0x06. Walking past the last block the device implements draws ERROR_RESP result code 0x58 (TOTAL_INCOHERENCE) — seen cross-vendor (Somfy Sunea awning + dimmer at block 0x80; a Velux window at block 0x0F and every block 0x80–0x8F). Read it as "that index does not exist on this device".
private_fn_sub (fn 0x09), index = data[1] Byte-identical to the private_fn fn 0x09 reply on both mains devices — the non-zero second payload byte changed nothing. On a Velux window a non-zero data[1] flipped the reply's data[0] to 0x2D and, at an irregular set of sub-indices, appended a 00 20 field — both undecoded.
get_info2 (0x56) 0x57 reply: 10 printable ASCII bytes (5143802A06, 5071662B09, 5165948A01) — a Somfy-internal reference / sw-version code, not a public catalogue number. The next two bytes (data[10..11]) are the packed device type/subtype this component already decodes via decode_packed_device_type() — verified: dimmer → LIGHT, awning → HORIZONTAL_AWNING, Velux window → WINDOW_OPENER. data[12..15] undecoded.
get_info1 (0x54) A VELUX window answered 0x55 with 00 00 00 00 00 00 00 00 00 30 03 00 00 00 (corpus velux_window_probe_metadata_replies). An RS100 Solar io answered with the ASCII bytes 5163341E02 and then 04 00 FF FF (corpus somfy_rs100_probe_get_info1_sx1262). Nothing decodes either yet.
subscribe_event (0x73) On an RS100 Solar io, both indexes are accepted behind a challenge and answered with a 0x71. Index 1: event 0x2005 with five data bytes 06 00 <hi> <lo> B9; the value in bytes 2–3 is 0 at night and 183 and 744 in daylight (corpus somfy_rs100_probe_subscribe_event_sx1262, somfy_rs100_probe_subscribe_event_daylight_sx1262). Index 0: event 0x2001 with one data byte, 100, while the battery read full (corpus somfy_rs100_probe_subscribe_event_battery_sx1262).
unsubscribe_event (0x73, action 00) Not yet sent to a device. Run it only after subscribe_event drew reports, then record whether they stop.
read_object (0x46/0x4A) Somfy Izymo dimmer, protocol version 3 (get_info1 byte 11 = 03): index 2 opened plainly (47 accepted, 16 bytes), the block reads were challenged and answered, and the record is 00 + "MODULE DIMMER" + padding. Indexes 0 and 1 were refused with status 3 and length 0. Index 3 returned the 14 bytes of the get_info1 answer and index 4 the 16 bytes of the get_info2 answer, byte for byte. Somfy RS100 Solar io, protocol version 4 (issue #156): index 0 returned all 150 bytes, index 1 54 of 67 bytes (the last block got no answer), indexes 3 and 4 14 and 16 bytes, index 3 equal to its get_info1 answer. A later round on that RS100, with the 650 ms pause, read indexes 1, 2 and 5 to 29: 21 of the 27 reads came back in full (object ids 0x8103, 0x8102, 0x8104, 0x8003, 0x8000, 0x8005, 0xC001, 0x6103, 0xA602, 0xA603, 0xA604, 0xA607, 0xA609, 0xA60B, 0xA60D, 0xA610, 0xA611, 0xA612, 0xA614, 0xA617 and 0xA618); three are longer (0xA601 366 bytes, 0xA613 431, 0xA615 341) and have not been read yet; they fit the 432-byte cap; 0xA606 was challenged and then lost, 0x6104 was never answered, and 0x6105 answered status 7 with length 0, twice and with no other transfer open, which the probe reports as an empty object. With the pause, 71 of 82 block requests (87 %) were answered on the first try. The objects read in full ran from 3 to 247 bytes.
register_00 / register_01 (0x20, read) register_00 swept 0x00–0x4F on an Atlantic Calypso Connecté water heater (issue #198), register_01 0x00–0x3F on an Atlantic Adelis towel dryer (issue #202). On both, a register the device lacks answers with an empty value. Record every answer per register, and retry silent ones closer.
general_info3 (0x58) Dimmer answered a real 0x59; a Somfy awning and a Velux window both replied ERROR_RESP result 0x08 (COMMAND_UNKNOWN: the device does not implement the command). Device-dependent.
private2 / private2_short (0x0C), index = modifier 0x0D reply; the main value is a stored parameter, not a live reading, and D4 00 in its place means no stored value. Byte-identical day vs night across 17 solar devices, and byte-identical between two window positions on a Velux window — its short form at modifier 0x03 read back the stored ventilation position (BA 00). The Sunea awning's short form at index 0x00 returned its stored favourite position. See "Reading a `private2` / `private2_short` reply" below.
status_mp_fp Unauthenticated, answered with a 0x04 and no challenge. A reply heard from a window: 04 2D 60 00 00 80 00 00 00. The main parameter is 00 00 for open and C8 00 for closed, followed by 80 00 00 00. Nothing is applied to the device record.
status_fp_high Unauthenticated, like status_mp_fp. The reply is reported raw (flags, the main parameter, then the parameter values) and nothing is applied to the device record.
limitation Unauthenticated, as heard from a KLF 200. Two replies heard from a window with no limitation active: 26 00 00 00 00 00 after the minimum request and 26 00 C8 00 00 00 after the maximum request. The result message adds a decoded line, limitation (assumed layout): param=MP value=100% (C8 00) originator=local_user(0x00) time=0x00 (30 s), which reads the five data bytes as parameter, value, originator and remaining time. Under rain protection the same window answered the minimum request with 26 00 BA 00 00 00 (93 %) and the maximum request unchanged. The value bytes read as described; the originator and remaining-time bytes were 00 even then, so those two stay an assumption, and the raw bytes stay beside every decoded value. A Somfy awning answers behind an authentication challenge with 26 05 00 00 00 00 (minimum) and 26 05 C8 00 00 00 (maximum) at every awning position: the first byte is 05, so the decode shows a non-main parameter. Nothing is applied to the device record.

What the replies do and don't carry. Across every probe and device tried so far — mains and solar, day and night — the only things recovered are position/target data and, via status_ext / private_fn data[8..10], the last commanding node ID. No reply has carried a per-device sensor value (battery, charge, luminance, temperature). Out-of-range indices answer result code 0x58 (TOTAL_INCOHERENCE). The remaining non-position unknowns — data[0] = 0x2D framing, the 00 20 private_fn_sub field, get_info2 data[12..15] — have no decode and no external source.

Reading a device object

read_object asks a device for one of its stored objects and prints the bytes. Somfy controllers read the two records at index 0 and 1 from every new actuator right after pairing; they list the events the actuator can report and the sensor types it carries. Nobody has published their byte layout, so this probe exists to capture it.

One call does three things: it opens the object, pulls it in blocks of up to 18 bytes, and closes the transfer. Index 2 is a 16-byte name record; indexes 3 and 4 read the object form of the two info answers (get_info1, get_info2); on a Somfy Izymo they return the same bytes. Use index 2 first to check that the whole flow works on your device before you read the records.

action: esphome.<your_node>_probe_device
data:
  device_id: "ABC123"
  probe: read_object
  index: "2"

The result carries the object id, the transfer's length and the bytes in response_hex; the log prints them 24 bytes to a line. The probe stops without reading when the device answers with an error, refuses the open, reports a length of 0, or announces more than 432 bytes. It never writes to the device and never changes the device's state in Home Assistant.

Expect devices to answer in different ways. An error answer or no reply at all means the device does not offer that object. Post the log lines, including a refusal, when you report a result.

The probe waits 650 ms before each block request and before the close. An RS100 Solar io missed every block request sent straight after its previous answer and answered the repeat, so the pause saves one long transmission per block (issue #156). An object of 150 bytes takes about 11 seconds to read.

Objects you can read

Each index opens one object. The class is the second byte of the open request: class 0 holds the records of the first ten rows, class 2 holds Somfy manufacturer objects.

index class object what it is
0 0 0x8100 Actuator capacity record
1 0 0x8103 Actuator state record
2 0 0x8003 Name record
3 0 0x8001 Object form of the get_info1 answer
4 0 0x8002 Object form of the get_info2 answer
5 to 9 0 0x8000, 0x8005, 0x8102, 0x8104, 0xC001 Objects an RS100 Solar io lists in its capacity record; all five were read in full on that device
10 to 12 2 0x6103, 0x6104, 0x6105 Somfy objects; on an RS100 Solar io 0x6103 was read in full, 0x6104 got no answer and 0x6105 answered status 7 with length 0
13 to 29 2 0xA601, 0xA602, 0xA603, 0xA604, 0xA606, 0xA607, 0xA609, 0xA60B, 0xA60D, 0xA610, 0xA611, 0xA612, 0xA613, 0xA614, 0xA615, 0xA617, 0xA618 (in this order) Somfy objects; on an RS100 Solar io 13 of the 17 were read in full, 0xA601 (366 bytes), 0xA613 (431) and 0xA615 (341) have not been read yet, and 0xA606 was lost on the air

A device that does not keep an object answers the open with status 3 and length 0, and nothing more is sent. The byte layouts of indexes 5 to 29 are not decoded; they are listed so their bytes can be captured.

Each block costs a transmission with a long preamble on a band with a duty-cycle limit. Read a few objects at a time rather than all of them at once.

Reading registers

register_00 and register_01 ask a device for one register over the private register protocol. The request is 0C 60 <family> <index>: 60 is the read direction. Neither probe can send the write direction (61) for any index, so they cannot change a setting on the device. They apply only to a register-protocol heater (such as an Atlantic AGILIA IO radiator) and to a domestic hot water device (node type 0x33); for a cover, light, switch, lock or any other kind the action is refused before anything is sent, and a sweep stops at that first refusal. See ADR 0063.

register_01 reads the family 0x01xx, where climate support finds the setpoint, mode and measurement registers of an AGILIA radiator; an Atlantic Adelis towel dryer answers it too (issue #202). register_00 reads the family 0x00xx, which an Atlantic Calypso Connecté water heater serves (issue #198).

action: esphome.<your_node>_probe_sweep
data:
  device_id: "ABC123"
  probe: register_01
  first_index: "0x00"
  last_index: "0x0F"

A device that serves the register answers with a 0x21 that repeats 0C 60 <family> <index> and then carries the value. The result prints those bytes after the header as value: xx xx, raw. A register the device does not have answers the same way with an empty value. No reply at all is a lost exchange, not a missing register: on a weak link whole runs of registers went unanswered and then answered with the board closer (issue #202), so retry those before you conclude anything. An error answer means the device does not serve that register at this address.

Domestic hot water devices. The hub has no entity for node type 0x33, so the device has to be registered before it can be probed. Declare it as a switch with its real type; the switch does nothing:

switch:
  - platform: home_io_control
    name: "Water heater probe handle"
    io_device_id: "ABC123"
    io_device_type: 0x33

Toggling this switch is refused and the hub sends it no status requests.

Which address answers. An AGILIA radiator answers register reads at the address one above the one it pairs under (ADR 0058). Which address a water heater answers at is not known. Probe the address it paired under first; if every read is refused or unanswered, declare the next address up the same way and probe that.

Last Device Event

With diagnostic_probes: true the hub adds a diagnostic text sensor, Last Device Event. It shows the most recent event report from a paired device, or frame from one that nothing else in this component handles, in the form

#3 t=5421 24635F 0x71 05 60 20 05 05 06 00 00 00 00

That is a running counter, the hub's uptime in seconds, the device, the command byte and the payload in hex. The counter makes two identical reports two different states, which Home Assistant needs to keep both in its history. The log carries the same frame at INFO level as Device event from ...; a build without diagnostic_probes: true logs it at DEBUG only.

  • A device event report is recorded whatever its destination. A report is a 0x71 whose event is not the position event 0x100A, or a 0x70. A 0x71 payload is a flags byte, a status byte, a two-byte event id, the length of the event data and the event data. The RS100 Solar io answered a subscription to the local sensor event with event 0x2005; ordinary position updates carry 0x100A.
  • With probes on, any other frame from a paired device that nothing handles is recorded too, so a report with an unexpected command byte is not lost.
  • A recorded frame never changes a device's position, state or battery; the entity only shows it (see ADR 0060). A 0x71 addressed to the hub is authenticated and acknowledged like every status update before it is recorded; any other recorded frame is never answered.
  • A report that arrives while the hub waits for the reply to its own request is recorded, and the hub asks once more for the reply it was waiting for.

Paste the Device event log lines and the sensor's history into an issue; they are what lets the reports be decoded.

Reading a private2 / private2_short reply

The reply command byte is CMD_PRIVATE2_RESP (0x0D), not 0x04. The reply data is a flags byte, a two-byte main value, and further bytes: 05 <main value> 00 00 in the short-form replies below. The main value is a stored parameter on the same 0x0000-0xC800 scale as a position (0xC800 is 100 %), not a live position reading. D4 00 in its place (POS_UNKNOWN) carries no value; the awning answers it at the indices it holds nothing for. It is not an echo of the request: the short-form request starts with D8.

  • Short form, index 0 (D8 00 00 00), favourite position. A Somfy Sunea awning answered 05 48 78 00 00 (about 36 %) while it stood at 0 %, so the value is not its current position. After the awning was moved to 25 % and that position was saved as My with the remote, the reply was 05 32 00 00 00 (0x3200, exactly 25 %). The Favorite Position button then drove the awning from 0 % to 25 %. After the awning was moved back to about 36 % and that position was saved as My again, the reply was 05 48 27 00 00, the position it stood at. Captures: somfy_awning_probe_private2_short_favorite_sx1262, somfy_awning_probe_private2_short_favorite_after_reprogram_sx1262 and somfy_awning_probe_private2_short_favorite_restored_sx1262.
  • Other indices. On the same awning index 7 and index 9 answered 6D D4 00 00 00: no stored value (somfy_awning_probe_private2_short_index7_sx1262, somfy_awning_probe_private2_short_index9_sx1262). A Somfy garage drive answered index 9 with 05 64 00 00 00 (50 %, the partial position its owner had set; wisniowski_moto1000_probe_private2_partial_position).
  • Long form (D4 00 80 D8 <modifier> 00). The Sunea awning and the Izymo dimmer answered 6D D4 00 00 00 at modifier 0x00 and 0x03, also after the My position was changed (somfy_awning_probe_private2_favorite_after_reprogram_lr1121). A real hub's 0x06 modifier draws a longer reply, for example 05 D4 00 80 C8 00 00 for 1F3807; the bytes after 80 look position-shaped and match the status_ext last-command tail. They are not battery or charge telemetry, and they do not vary over a day/night cycle (checked on 17 solar devices). 0x0C is not a live-telemetry read.
  • Izymo dimmer. Its short form at index 0 answered 05 70 00 00 00 (56 %), so a light replies with a value too (somfy_izymo_dimmer_probe_private2_short_favorite_sx1262). The dimmer's remote was not used, so it is not confirmed that this value is its stored favourite level.

The favourite-position reading is confirmed on the Sunea only. Treat it as experimental on any other device until a second device confirms it. The component does not read or show it; the probe only logs the reply.

Widen carefully

The starting values above are the safest available for each probe — for status_ext and private2/private2_short because a real hub sends exactly those bytes to real motors routinely; for private_fn because those two function IDs have drawn harmless position replies on every device tried. Widening beyond them is a separate, deliberate decision, not something to do by default — and when you do, prefer the dimmer/light over a motor: a wrong write-shaped result on a light is visible and trivially reversible, while a motor's stored configuration is not.

private_fn_sub, status_ext_fn6 and status_ext_fn9 differ from status_ext/private_fn in that only their shape, not their function ID or sub-index, is field-observed — so they are one byte further from known-safe traffic than anything else in this table. The same "prefer the dimmer/light over a motor" advice applies, with more reason.

Expect a long block from probe_sweep

A full-range sweep can block the ESPHome loop (API, other components, OTA) for on the order of a minute at default tuning, longer if a device never answers or if exchange_start_response_wait_ms has been raised — up to 16 indices, each up to 3 retries at the configured response-wait time, plus a spacing delay between indices. This is accepted deliberately for this maintainer-triggered, explicitly-opted-in diagnostic rather than restructured into scheduled steps — expect a warning about a long-blocking operation, and expect other Home Assistant traffic against this device to stall for the duration. probe_device (a single index) does not have this problem; reach for probe_sweep only when you actually need the range in one gesture.

See also