Home IO Control
ESPHome add-on for IO-Homecontrol devices
|
Sending opcodes this project has not fully decoded yet, to learn what a device answers. This is a deliberately gated feature: probes are read-only reconnaissance, not control.
home_io_control.diagnostic_probes: true enables two Home Assistant actions, probe_device and probe_sweep, for sending a handful of opcodes this project has observed on the wire but never fully decoded, and for reading back the raw, uninterpreted reply. This is protocol-research tooling for closing exactly that kind of open question on hardware you own — see ADR 0024 for how it is gated and isolated from the rest of this component.
home_io_control: node_id: "C0FFEE" system_key: "..." diagnostic_probes: true
It only ever targets a device already paired to this hub. probe_device/probe_sweep resolve their target the same way every other management action does — there is no path from this instrumentation to a device this hub has not already paired with and does not already hold a key for. Every probe additionally refuses while the target device's last known state is "moving" — an unknown frame is never sent into a device state machine that is already mid-transaction. This is the device's last reported movement state, not a check on anything in flight: it never applies to a light/switch, and it can be stale if the device was last moved from a physical remote the hub never saw.
Same node-scoped naming as every other action in this component — see Home Assistant actions for the full explanation of how <node_name> is derived from esphome.name. For a config with name: hioc-heltec-v2:
action: esphome.hioc_heltec_v2_probe_device data: device_id: "FEEB1E" probe: "private2" index: "0x09"
probe_sweep takes a range instead of a single index:
action: esphome.hioc_heltec_v2_probe_sweep data: device_id: "FEEB1E" probe: "status_ext" first_index: "0x00" last_index: "0x01"
| probe | Sends | index selects | Start with | Evidence for the starting values |
|---|---|---|---|---|
| private_fn | CMD_PRIVATE (0x03) with a chosen function ID | The function ID | 0x06 or 0x09 | Not field-observed on the wire — every captured CMD_PRIVATE frame uses function ID 0x03. On real hardware (17 solar devices plus this project's own mains motors) 0x06 and 0x09 returned a stored/target position: 0x06 is always 00 00; 0x09 tracked shutters closing. Not a battery probe. |
| private_fn_sub | CMD_PRIVATE (0x03) at function ID 0x09, with a chosen second payload byte | The second payload byte (data[1]) | 0x01 | Not field-observed. Every CMD_PRIVATE frame ever captured — by this project or by a real hub — has 0x00 in this byte, so nothing on air pins down what it means. Treat any reply as uninterpreted. |
| status_ext | Extended CMD_PRIVATE at selector 0x80 | The block/N value | 0x00 and 0x01 | Field-observed: real hubs send exactly these two values to real motors. |
| status_ext_fn6 | Extended CMD_PRIVATE at selector 0x80, function ID 0x06 | The block/N value | 0x00, then 0x80 | The 4-byte extended shape is field-observed: a real hub sends 03 80 00 00 and 03 80 01 00 to real motors (40 frames across two logs), and the 0x80 at data[1] is what makes the 0x04 reply carry its trailing extended block. The function ID 0x06 in that shape is not field-observed — no hub has ever been seen sending it. probe_sweep caps a run at 16 consecutive indices, so 0x80 is out of reach of a sweep starting at 0 — send it with probe_device (or sweep 0x80–0x8F explicitly). |
| status_ext_fn9 | Extended CMD_PRIVATE at selector 0x80, function ID 0x09 | The block/N value | 0x00, then 0x01 | Same shape evidence as status_ext_fn6; the function ID 0x09 in this shape is not field-observed. On the ordinary 3-byte form, 0x09 returned a stored position on every device tested — not a battery value. |
| get_info1 | CMD_GET_INFO1 (0x54), no payload | — (probe_device only; probe_sweep rejects it) | — | Field-observed: a real hub sends 0x54 on air. No 0x55 answer has ever been captured, so this probe may well draw an 0xFE "opcode not supported" or nothing at all — that is itself a result worth recording. |
| get_info2 | CMD_GET_INFO2 (0x56), no payload | — (probe_device only; probe_sweep rejects it) | — | The request has never been captured; it rests on the protocol's even=request / odd=answer pairing rule. The answer 0x57 is captured and carries a leading ASCII reference string followed by the packed type/subtype bytes this component already decodes. Reply strings are wire-observable and citable as-is; do not attempt to resolve one to a model name from any non-public source. |
| general_info3 | CMD_GET_GENERAL_INFO3 (0x58), no payload | — (probe_device only; probe_sweep rejects it) | — | — |
| private2 | CMD_PRIVATE2 (0x0C), long wire form | The modifier byte | 0x06, then 0x05, 0x09 | Field-observed: a real hub sends exactly these modifier bytes in the long form to real motors (e.g. request data D4 00 80 D8 06 00). This component's own POS_FAVORITE/POS_VENT_MODIFIER values (0x00/0x03) are not what a hub sends, and never draw the extended block described below. |
| private2_short | CMD_PRIVATE2 (0x0C), short wire form | Same as private2 | 0x03, then 0x09 | Field-observed: a real hub sends the short form with these modifiers (e.g. request data D8 03 00 00). |
There is deliberately no probe for 0x4A. It reads a buffer in chunks between two controllers and has been seen on air in a VELUX KLR 200 copy session. What it does to an actuator is unknown, and the command block around it includes write commands, so sending it is not worth the risk. See ADR 0024.
A get_info2 reply (0x57) leads with printable ASCII: paste the raw hex into the corpus and read the string off it, but record only what the wire shows — do not resolve it to a model name from any non-public source.
A running record of what these frames actually draw back — as much as is understood so far.
| probe / index | what came back |
|---|---|
| private_fn fn 0x06 | data[2..3] = 00 00 on every device probed — two mains motors of ours plus 17 solar shutters via a field reporter. No content. |
| private_fn fn 0x09 | data[2..3] = a stored position: D8 0A on the dimmer (0xD8 == POS_FAVORITE), 58 22 on the awning; solar shutters in the field data tracked their real position as they closed. |
| status_ext (fn 0x03), index = block | Field-observed selector. Device-dependent framing (see status_ext_fn9). Blocks 0x00/0x01 are what real hubs send. |
| status_ext_fn9, index = block | Reply framing is device-dependent: some devices answer data[0] = the 0x04/0x05 stopped-flag byte with an 0x80-tagged block, others answer data[0] = 0x2D with no block. On the dimmer the 0x80 block tail changes with the index (… 80 00 00 00 at 0x00 → … 80 D8 06 00 at 0x01) — first time one of our own probes drew a non-empty, index-selected block; content is position family (D8 06). The awning ignores the index. A Velux window kept data[2..3] = its live position and appended an index-selected 0x80 tail (78 00 / 50 00 / C8 00 at different blocks — position-family values, meaning undecoded). |
| status_ext_fn6, index = block | data[2..3] zeroed, same as private_fn fn 0x06. Walking past the last block the device implements draws ERROR_RESP result code 0x58, mapped as INVALID_FUNCTION_INDEX — seen cross-vendor (Somfy Sunea awning + dimmer at block 0x80; a Velux window at block 0x0F and every block 0x80–0x8F). Not a documented result code; treat it purely as "that index does not exist on this device". |
| private_fn_sub (fn 0x09), index = data[1] | Byte-identical to the private_fn fn 0x09 reply on both mains devices — the non-zero second payload byte changed nothing. On a Velux window a non-zero data[1] flipped the reply's data[0] to 0x2D and, at an irregular set of sub-indices, appended a 00 20 field — both undecoded. |
| get_info2 (0x56) | 0x57 reply: 10 printable ASCII bytes (5143802A06, 5071662B09, 5165948A01) — a Somfy-internal reference / sw-version code, not a public catalogue number. The next two bytes (data[10..11]) are the packed device type/subtype this component already decodes via decode_packed_device_type() — verified: dimmer → LIGHT, awning → HORIZONTAL_AWNING, Velux window → WINDOW_OPENER. data[12..15] undecoded. |
| get_info1 (0x54) | Not yet sent to a device by this project. No 0x55 answer has ever been captured from anything. |
| general_info3 (0x58) | Dimmer answered a real 0x59; a Somfy awning and a Velux window both replied ERROR_RESP result 0x08 (ERROR_DURING_EXECUTION, "opcode not supported"). Device-dependent. |
| private2 / private2_short (0x0C), index = modifier | 0x0D reply; D4 00 is the request's own leading bytes echoed back; optional 0x80 block is position family. Byte-identical day vs night across 17 solar devices, and byte-identical between two window positions on a Velux window (a stored parameter, not a live reading) — its short form at modifier 0x03 read back the stored ventilation position (BA 00). See "Reading a `private2` reply" below. |
What the replies do and don't carry. Across every probe and device tried so far — mains and solar, day and night — the only things recovered are position/target data and, via status_ext / private_fn data[8..10], the last commanding node ID. No reply has carried a per-device sensor value (battery, charge, luminance, temperature). Out-of-range indices answer result code 0x58 (INVALID_FUNCTION_INDEX — self-derived from the cross-vendor pattern, no external source). The remaining non-position unknowns — data[0] = 0x2D framing, the 00 20 private_fn_sub field, get_info2 data[12..15] — have no decode and no external source.
The reply command byte is CMD_PRIVATE2_RESP (0x0D), not 0x04. In every reply captured so far the two bytes right after the flags byte are D4 00 — this is the request's own leading payload bytes echoed back, not a POS_UNKNOWN position reading. The per-device content, when there is any, rides in an optional 0x80-tagged block after that echo:
The block content observed to date is position-family (C8 00 00, 72 49 00) and matches the status_ext last-command tail — it is not battery/charge telemetry, and it does not vary over a day/night cycle (checked on 17 solar devices). 0x0C is not a live-telemetry read.
The starting values above are the safest available for each probe — for status_ext and private2/private2_short because a real hub sends exactly those bytes to real motors routinely; for private_fn because those two function IDs have drawn harmless position replies on every device tried. Widening beyond them is a separate, deliberate decision, not something to do by default — and when you do, prefer the dimmer/light over a motor: a wrong write-shaped result on a light is visible and trivially reversible, while a motor's stored configuration is not.
private_fn_sub, status_ext_fn6 and status_ext_fn9 differ from status_ext/private_fn in that only their shape, not their function ID or sub-index, is field-observed — so they are one byte further from known-safe traffic than anything else in this table. The same "prefer the dimmer/light over a motor" advice applies, with more reason.
A full-range sweep can block the ESPHome loop (API, other components, OTA) for on the order of a minute at default tuning, longer if a device never answers or if exchange_start_response_wait_ms has been raised — up to 16 indices, each up to 3 retries at the configured response-wait time, plus a spacing delay between indices. This is accepted deliberately for this maintainer-triggered, explicitly-opted-in diagnostic rather than restructured into scheduled steps — expect a warning about a long-blocking operation, and expect other Home Assistant traffic against this device to stall for the duration. probe_device (a single index) does not have this problem; reach for probe_sweep only when you actually need the range in one gesture.