esphome::home_io_control::DiagnosticProbes Class Reference

Sends diagnostic probe frames to already-paired devices and reports the raw replies. More...

#include <diagnostic_probes.h>

Collaboration diagram for esphome::home_io_control::DiagnosticProbes:

Public Member Functions

 DiagnosticProbes (const uint8_t *node_id, ExchangeEngine &engine, DeviceRegistry &registry, const bool *initialized, DiagnosticProbesHub hub)
 Construct with the collaborators a probe exchange needs.
 DiagnosticProbes (const DiagnosticProbes &)=delete
DiagnosticProbes & operator= (const DiagnosticProbes &)=delete
ManagementActionResult probe_device (const std::string &device_id, const std::string &probe, const std::string &index)
 Send a single diagnostic probe frame to an already-paired device and report the raw reply.
ManagementActionResult probe_sweep (const std::string &device_id, const std::string &probe, const std::string &first_index, const std::string &last_index)
 Walk a bounded index range, one probe_device() call per index, in one user gesture.

Detailed Description

Sends diagnostic probe frames to already-paired devices and reports the raw replies.

Non-copyable for the same reason as ManagementActions: it holds references into hub members.

Definition at line 47 of file diagnostic_probes.h.

Constructor & Destructor Documentation

◆ DiagnosticProbes() [1/2]

esphome::home_io_control::DiagnosticProbes::DiagnosticProbes ( const uint8_t * node_id,
ExchangeEngine & engine,
DeviceRegistry & registry,
const bool * initialized,
DiagnosticProbesHub hub )

Construct with the collaborators a probe exchange needs.

Parameters
node_idController 3-byte node ID, owned by the hub.
engineShared exchange engine for radio transactions.
registryDevice registry for device lookups.
initializedPointer to the hub's initialized flag.
hubThe three injected hub calls.

Definition at line 439 of file diagnostic_probes.cpp.

◆ DiagnosticProbes() [2/2]

esphome::home_io_control::DiagnosticProbes::DiagnosticProbes ( const DiagnosticProbes & )
delete
Here is the call graph for this function:

Member Function Documentation

◆ operator=()

DiagnosticProbes & esphome::home_io_control::DiagnosticProbes::operator= ( const DiagnosticProbes & )
delete
Here is the call graph for this function:

◆ probe_device()

ManagementActionResult esphome::home_io_control::DiagnosticProbes::probe_device ( const std::string & device_id,
const std::string & probe,
const std::string & index )

Send a single diagnostic probe frame to an already-paired device and report the raw reply.

Protocol-research instrumentation for opcodes this codebase has not decoded — see docs/diagnostic-probes.md and ADR 0024. Refuses unless this build was configured with diagnostic_probes: true (DiagnosticProbesHub::probes_enabled), and separately refuses while the target device is moving (!effective_is_stopped(*dev)) — an unknown frame into a mid-transaction device state machine is the one avoidable way a read-shaped probe could cause harm. That is the device's last reported movement state or a standing hub prediction that it is moving (a command the hub just issued, not yet confirmed): both warrant the same refusal. It is always "stopped" (never refuses) for a light/switch, and the reported state can be stale if the device was last moved from a physical remote the hub never saw. Routes the response straight into result.message as raw hex; it is never passed to the hub's status decoder (this class holds no hub pointer, only the three calls of DiagnosticProbesHub, and none of them applies a status), so a probe can never be misread as a position update. verified is always false: the whole point is that the reply's meaning is not yet known.

probe selects the frame builder:

  • "private_fn": create_private_function(), index = function ID (Q0).
  • "private_fn_sub": create_private_function() at function ID 0x09, index = the second payload byte (data[1]) — an undecoded parameter-addressing byte no project has ever sent as non-zero.
  • "status_ext": create_get_status_extended() at the field-observed selector 0x80, index = block/N (Q1). The selector-0x20 tilt control is create_get_status_tilt() (already shipped) and is not part of this probe.
  • "status_ext_fn6" / "status_ext_fn9": create_get_status_extended() at selector 0x80 with function ID 0x06 / 0x09 instead of the usual 0x03, index = block/N. The 4-byte shape is field-observed; the function ID in it is not.
  • "get_info1": create_get_info1() (CMD_GET_INFO1 0x54, no payload), index ignored.
  • "get_info2": create_get_info2() (CMD_GET_INFO2 0x56, no payload), index ignored.
  • "general_info3": create_general_info3(), index ignored (Q2).
  • "private2": create_private2_read() long form, index = modifier (Q3).
  • "private2_short": create_private2_read() short form, index = modifier (Q3).
  • "status_mp_fp": create_status_mp_fp_read() (CMD_PRIVATE function 0x01, FPI1 mask 0xFE: main parameter plus FP1-FP7), index ignored. The reply is reported raw like every probe reply and never applied to the device record (ADR 0024).
  • "status_fp_high": the same request with FPI1 0x00 (main parameter only) and index as the FPI2 bitmap (bit 7 = FP9 ... bit 0 = FP16, 1 to 7 bits set; anything else is rejected). Not sweepable, an index is a bitmap. The FPI2 variant has not been seen on air; the reply is reported raw and never applied.
  • "limitation": create_limitation_status_read() (CMD_LIMITATION_STATUS_REQ 0x25), index 0 = resulting minimum, 1 = resulting maximum (any other index is rejected, a sweep reaching past 1 is rejected whole). The reply is reported raw plus a decode labelled "assumed layout" in ManagementActionResult::decoded; it is never applied to the device record.
  • "subscribe_event": create_subscribe_event() (CMD_SUBSCRIBE_EVENT 0x73), index 0 = battery level event 0x2001, 1 = local sensor event 0x2005 (any other index is rejected). It changes device state: it stores a subscription with no confirmed way to remove it, so it is not sweepable and the builder accepts only those two events (ADR 0060). It is sent once: a try the device authenticated is never repeated, so silence after acceptance is reported as "accepted but no response". Whatever the device reports afterwards is recorded by the device-event recorder, never applied to the device record.
  • "unsubscribe_event": create_unsubscribe_event(), the same request with action byte 0x00, same index mapping and the same guards. An untested guess at undoing a subscription; whether it works shows only in whether the device's reports stop.
  • "read_object": the data-transport read of ADR 0062. index is a row of TRANSFER_READABLE_OBJECTS: 0 = actuator capacity record (object 0x8100), 1 = actuator state record (0x8103), 2 = name record (0x8003, there to prove the flow before the other two are trusted), 3 = general info 1 (0x8001), 4 = general info 2 (0x8002), 5 to 29 = further class-0 and Somfy manufacturer objects. One call opens the object (CMD_TRANSFER_OPEN), pulls its blocks (CMD_UNKNOWN4A_REQ, counting down) and closes it; the bytes are reported raw in response_hex and logged, never interpreted or applied to the device record. Not sweepable; an object announced longer than PROBE_READ_OBJECT_MAX_BYTES is closed unread. The write twin of the block (0x48, and a 0x4A that carries data) has no builder.
  • "register_00" / "register_01": a read of register 0x00<index> / 0x01<index> over CMD_WRITE_PRIVATE (0C 60 <hi> <lo>, ADR 0063). The direction byte is the read constant and cannot be set to the write direction by any input (encode_heating_register_read()). Refused for a device that is neither a register-protocol heater nor a domestic hot water device (device_accepts_register_probe()); sweepable. A 0x21 that echoes the register also reports its value bytes raw in decoded. Family 0x00xx is untested; 0x01xx is the one climate support reads.

index is a string, not an int, because ManagementServiceDescriptor:: encode_list_service_response() hardcodes every native-API action argument as SERVICE_ARG_TYPE_STRING (see management_actions.cpp) — parsed here via parse_probe_index() (diagnostic_probes.cpp), which accepts both "6" and "0x06".

Parameters
device_idTarget device ID (hex string, case-insensitive).
probeOne of the probe names above.
indexFunction ID / selector block / modifier, depending on probe; a decimal or 0x-prefixed hex string. Ignored for "general_info3".
Returns
Structured result whose message carries the attempt count, and on a reply, the response command byte and full raw hex.

Definition at line 443 of file diagnostic_probes.cpp.

Here is the call graph for this function:

◆ probe_sweep()

ManagementActionResult esphome::home_io_control::DiagnosticProbes::probe_sweep ( const std::string & device_id,
const std::string & probe,
const std::string & first_index,
const std::string & last_index )

Walk a bounded index range, one probe_device() call per index, in one user gesture.

Answers Q0/Q1/Q3 (the multi-value probes) without one native-API call per value. Bounded to PROBE_SWEEP_MAX_INDICES indices and spaced PROBE_SWEEP_DELAY_MS apart — this transmits on a shared ISM band to what may be a battery device, so a tight loop is antisocial and would also keep the device awake and skew results. Each index costs up to EXCHANGE_RETRY_COUNT frames (proto_timing.h), same as a single probe_device() call.

Note
This blocks the ESPHome loop (API, other components, OTA) for the whole sweep, same blocking-exchange model as every other management action (ADR 0013) — but a full sweep multiplies it: worst case (every index silent) is roughly PROBE_SWEEP_MAX_INDICES * (EXCHANGE_RETRY_COUNT * exchange_start_response_wait_ms + (EXCHANGE_RETRY_COUNT-1) * EXCHANGE_RETRY_DELAY_MS + PROBE_SWEEP_DELAY_MS), on the order of a minute at default tuning and longer if exchange_start_response_wait_ms is raised. Accepted deliberately for this maintainer-triggered, explicitly-opted-in diagnostic (diagnostic_probes: true) rather than restructured into scheduled steps — see docs/diagnostic-probes.md, which states this to the user rather than leaving it to be discovered as a frozen dashboard.
Parameters
device_idTarget device ID (hex string, case-insensitive).
probeOne of probe_device()'s probe names.
first_indexFirst index in the sweep (inclusive), same string format as probe_device().
last_indexLast index in the sweep (inclusive).
Returns
Structured result whose message is one line per index: answered / error-coded / silent / refused.

Definition at line 661 of file diagnostic_probes.cpp.

Here is the call graph for this function:

The documentation for this class was generated from the following files: