Home IO Control
ESPHome add-on for IO-Homecontrol devices
Loading...
Searching...
No Matches
home_io_control.hub_validators Namespace Reference

Functions

 validate_radio_transport (config)
 validate_fem (config)
 heating_profile_has_window (device_type, subtype)
 _resolve_named_or_raw_token (token, options, max_value=0xFF)
 _resolve_device_type_token (token)
 validate_device_type (value)
 validate_manufacturer (value)
 device_type_expression (value)
 validate_node_id (value)
 validate_system_key (value)
 validate_device_id (value)
 inherit_esphome_device (companion_config, parent_config)
 validate_linked_remote_entry (value)
 _validate_min_interval (value, minimum_ms, key)
 validate_status_poll_interval (value)
 validate_rain_sensor_poll_interval (value)

Variables

 _LOGGER = logging.getLogger(__name__)
dict PA_PIN_OPTIONS
dict RADIO_TYPE_OPTIONS
 SPI_RADIO_TYPES = frozenset({"sx1276", "sx1262", "lr1121"})
dict TCXO_VOLTAGE_OPTIONS
 FemProfile = home_io_control_ns.enum("FemProfile", is_class=True)
dict FEM_PROFILES
dict FEM_REQUIRED_PINS
dict FEM_TX_POWER_MAX_QUIET
int DEVICE_TYPE_MAX = 0x3FF
dict DEVICE_TYPE_OPTIONS
dict HEATING_WINDOW_PROFILES
dict RENAMED_DEVICE_TYPES
dict MANUFACTURER_OPTIONS
dict ONEWAY_WIRE_PROFILE_MANUFACTURERS

Function Documentation

◆ _resolve_device_type_token()

_resolve_device_type_token ( token)
protected
Resolve a lowercase, stripped device-type token (name or raw int/hex string) to 0-1023.

Single source of truth for the "named value from DEVICE_TYPE_OPTIONS, else raw integer"
acceptance rule shared by validate_device_type() (io_device_type) and
validate_linked_remote_entry() (the class:<device_type> linked-remotes form) — both accept
the exact same set of device-type spellings, so the lookup lives here once.
@raises ValueError if token is neither a known name nor a parseable integer.
@raises cv.Invalid if token is a renamed device-type name (naming the new one), or parses as an
integer but is out of range 0-1023.

Definition at line 286 of file hub_validators.py.

Here is the call graph for this function:

◆ _resolve_named_or_raw_token()

_resolve_named_or_raw_token ( token,
options,
max_value = 0xFF )
protected
Resolve a lowercase, stripped token (a name from `options`, or a raw int/hex string) to
an integer 0-`max_value`.

Shared "named value, else raw integer" acceptance rule: validate_device_type()/
validate_linked_remote_entry() (DEVICE_TYPE_OPTIONS) and validate_manufacturer()
(MANUFACTURER_OPTIONS) are the same shape of small, protocol-defined enum with an escape
hatch for values this project hasn't named yet, so the lookup lives here once.
@raises ValueError if token is neither a known name nor a parseable integer.
@raises cv.Invalid if token parses as an integer but is out of range.

Definition at line 270 of file hub_validators.py.

◆ _validate_min_interval()

_validate_min_interval ( value,
minimum_ms,
key )
protected
Parse a time period and reject anything shorter than minimum_ms, naming the key.

Definition at line 439 of file hub_validators.py.

◆ device_type_expression()

device_type_expression ( value)
Generate a C++ static_cast expression for a validated device type.

Definition at line 343 of file hub_validators.py.

◆ heating_profile_has_window()

heating_profile_has_window ( device_type,
subtype )
True when the heating profile of (io_device_type value, io_subtype) has the window companions.

Definition at line 215 of file hub_validators.py.

◆ inherit_esphome_device()

inherit_esphome_device ( companion_config,
parent_config )
Propagate the parent entity's ESPHome sub-device (YAML `device_id:`) onto a hand-built
companion config dict, so the companion entity groups under the same HA device as its parent.

Lives here rather than in platform_common.py: it is needed by button.py's pairing-result
sensor, which is not a device-bound platform and would otherwise have to import the whole
platform-schema module for a four-line helper. platform_common.py re-exports it so cover.py's
existing import keeps working.

Companion entities (diagnostic sensors, cover favorite/vent buttons, ...) are built from
dicts fed straight to e.g. new_text_sensor()/new_button() rather than through the platform's
own cv.Schema(), so they never go through ENTITY_BASE_SCHEMA and never pick up `device_id:`
on their own. esphome.core.entity_helpers.setup_entity() reads it with
`config.get(CONF_DEVICE_ID)`, a truthiness check, so an explicit `None` and an absent key
behave identically; omitted here rather than set to None just to keep the dict shape
identical to a companion with no sub-device at all.

Deliberately not called anywhere for the hub-level dynamic entities (1W identity buttons/
sensors, the arming switches, LR1121 firmware controls, tuning numbers/selects): none of their
parent configs carry a `device_id:` schema slot, since those entities aren't attached to a
single cover/light/switch/lock to inherit one from. `device_id:` grouping is scoped to the
four device-bound platforms; hub-level entities always live on ESPHome's main device.

Definition at line 386 of file hub_validators.py.

◆ validate_device_id()

validate_device_id ( value)
Validate io_device_id as exactly 6 hex characters (3 bytes).

Definition at line 374 of file hub_validators.py.

◆ validate_device_type()

validate_device_type ( value)
Validate io_device_type as a named string or integer 0-1023.

Definition at line 302 of file hub_validators.py.

Here is the call graph for this function:

◆ validate_fem()

validate_fem ( config)
Cross-key validation for `fem:` (ADR 0035): which front-end part's control behaviour the
SX1262 driver applies to fem_pa_pin (and, for the two parts that have one, fem_en_pin), never
which GPIO numbers to use for them -- those are always the board package's job, the same as
every other radio pin. Requires radio_type: sx1262 (the raw FEM pins are silently ignored on
every other chip -- select_and_construct_radio_() only ever hands them to RadioSX1262 -- so a
mismatched radio_type would configure hardware the driver never drives), and that every pin
this profile's behaviour needs is actually present, naming exactly which is missing rather
than leaving the driver to silently no-op on a null pin. Also warns when tx_power looks likely
to push this FEM's antenna-port power over a typical 868 MHz SRD limit -- radio_sx1262.cpp's
own init() logs the actual per-part estimate this warning can only gesture at without knowing
the front-end part's exact gain table here too.

Definition at line 127 of file hub_validators.py.

◆ validate_linked_remote_entry()

validate_linked_remote_entry ( value)
Validate a linked_remotes entry: either a device ID or 'class:<device_type>'.

The class form matches how 1W remotes address a typed broadcast (e.g. "all awnings")
rather than a single node, so one entry can cover many same-type devices without
enumerating each one. Shares _resolve_device_type_token() with validate_device_type()
so a type without a named YAML alias yet (e.g. discovered via pairing) can still be
class-linked. Normalized to 'class:0x<HH>' (uppercase hex) so wire_device_binding() can
parse the type directly without a second DEVICE_TYPE_OPTIONS lookup; bare device IDs are
validated exactly as before and behave identically.

Definition at line 414 of file hub_validators.py.

Here is the call graph for this function:

◆ validate_manufacturer()

validate_manufacturer ( value)
Validate manufacturer as a named string (MANUFACTURER_OPTIONS) or integer 0-255.

Mirrors validate_device_type() exactly (same "name, else raw integer" shape via
_resolve_named_or_raw_token()) — a manufacturer ID is the same kind of small,
protocol-defined enum, it just has no linked_remotes-style second caller.

Definition at line 321 of file hub_validators.py.

Here is the call graph for this function:

◆ validate_node_id()

validate_node_id ( value)
Validate node_id as exactly 6 hex characters (3 bytes).

Definition at line 350 of file hub_validators.py.

◆ validate_radio_transport()

validate_radio_transport ( config)
Require the SPI device keys for a radio on the SPI bus. The schema takes them as optional
(``spi.spi_device_schema(False, ...)``) so that the requirement follows ``radio_type`` here,
in one place, rather than being hard-wired into the schema for every radio.

Definition at line 113 of file hub_validators.py.

◆ validate_rain_sensor_poll_interval()

validate_rain_sensor_poll_interval ( value)
Validate rain_sensor_poll_interval is at least MIN_RAIN_SENSOR_POLL_INTERVAL_MS.

Definition at line 454 of file hub_validators.py.

Here is the call graph for this function:

◆ validate_status_poll_interval()

validate_status_poll_interval ( value)
Validate status_poll_interval is at least MIN_STATUS_POLL_INTERVAL_MS.

Definition at line 447 of file hub_validators.py.

Here is the call graph for this function:

◆ validate_system_key()

validate_system_key ( value)
Validate system_key as exactly 32 hex characters (16 bytes).

Definition at line 362 of file hub_validators.py.

Variable Documentation

◆ _LOGGER

home_io_control.hub_validators._LOGGER = logging.getLogger(__name__)
protected

Definition at line 33 of file hub_validators.py.

◆ DEVICE_TYPE_MAX

int home_io_control.hub_validators.DEVICE_TYPE_MAX = 0x3FF

Definition at line 176 of file hub_validators.py.

◆ DEVICE_TYPE_OPTIONS

dict home_io_control.hub_validators.DEVICE_TYPE_OPTIONS
Initial value:
= {
"unknown": 0x00,
"interior_venetian_blind": 0x01,
"roller_shutter": 0x02,
"vertical_exterior_awning": 0x03,
"window_opener": 0x04,
"garage_opener": 0x05,
"light": 0x06,
"gate_opener": 0x07,
"rolling_door_opener": 0x08,
"lock": 0x09,
"vertical_interior_blind": 0x0A,
"dual_roller_shutter": 0x0D,
"heating_temperature_interface": 0x0E,
"on_off_switch": 0x0F,
"horizontal_awning": 0x10,
"exterior_venetian_blind": 0x11,
"louvre_blind": 0x12,
"curtain_track": 0x13,
"exterior_heating": 0x15,
"heat_pump": 0x16,
"intrusion_alarm": 0x17,
"swinging_shutter": 0x18,
"sliding_window": 0x1B,
"bioclimatic_pergola": 0x1D,
"electrical_heater": 0x34,
}

Definition at line 178 of file hub_validators.py.

◆ FEM_PROFILES

dict home_io_control.hub_validators.FEM_PROFILES
Initial value:
= {
"none": FemProfile.NONE,
"gc1109": FemProfile.GC1109, # Heltec WiFi LoRa 32 V4.2
"kct8103l": FemProfile.KCT8103L, # Heltec WiFi LoRa 32 V4.3 / V4 R8
"xy16p35": FemProfile.XY16P35, # LilyGO T-Beam 1W SX1262
}

Definition at line 78 of file hub_validators.py.

◆ FEM_REQUIRED_PINS

dict home_io_control.hub_validators.FEM_REQUIRED_PINS
Initial value:
= {
"gc1109": (CONF_VFEM_PIN, CONF_FEM_EN_PIN, CONF_FEM_PA_PIN),
"kct8103l": (CONF_VFEM_PIN, CONF_FEM_EN_PIN, CONF_FEM_PA_PIN),
"xy16p35": (CONF_VFEM_PIN, CONF_FEM_PA_PIN),
}

Definition at line 93 of file hub_validators.py.

◆ FEM_TX_POWER_MAX_QUIET

dict home_io_control.hub_validators.FEM_TX_POWER_MAX_QUIET
Initial value:
= {
"gc1109": 3,
"kct8103l": 1,
"xy16p35": 0,
}

Definition at line 106 of file hub_validators.py.

◆ FemProfile

home_io_control.hub_validators.FemProfile = home_io_control_ns.enum("FemProfile", is_class=True)

Definition at line 77 of file hub_validators.py.

◆ HEATING_WINDOW_PROFILES

dict home_io_control.hub_validators.HEATING_WINDOW_PROFILES
Initial value:
= {
"electrical_heater": 1,
}

Definition at line 210 of file hub_validators.py.

◆ MANUFACTURER_OPTIONS

dict home_io_control.hub_validators.MANUFACTURER_OPTIONS
Initial value:
= {
"velux": 0x01,
"somfy": 0x02,
"honeywell": 0x03,
"hormann": 0x04,
"assa_abloy": 0x05,
"niko": 0x06,
"window_master": 0x07,
"renson": 0x08,
"ciat": 0x09,
"secuyou": 0x0A,
"overkiz": 0x0B,
"atlantic_group": 0x0C,
}

Definition at line 246 of file hub_validators.py.

◆ ONEWAY_WIRE_PROFILE_MANUFACTURERS

dict home_io_control.hub_validators.ONEWAY_WIRE_PROFILE_MANUFACTURERS
Initial value:
= {
MANUFACTURER_OPTIONS["somfy"],
MANUFACTURER_OPTIONS["velux"],
}

Definition at line 264 of file hub_validators.py.

◆ PA_PIN_OPTIONS

dict home_io_control.hub_validators.PA_PIN_OPTIONS
Initial value:
= {
"BOOST": 0x80,
"RFO": 0x00,
}

Definition at line 36 of file hub_validators.py.

◆ RADIO_TYPE_OPTIONS

dict home_io_control.hub_validators.RADIO_TYPE_OPTIONS
Initial value:
= {
"sx1276": "sx1276",
"sx1262": "sx1262",
"lr1121": "lr1121",
}

Definition at line 41 of file hub_validators.py.

◆ RENAMED_DEVICE_TYPES

dict home_io_control.hub_validators.RENAMED_DEVICE_TYPES
Initial value:
= {
"screen": (
"device type 'screen' no longer exists: type 11 is a secure configuration device, not an "
"actuator. Use the type Scan Paired Devices reports for your device, usually "
"'vertical_exterior_awning' or 'vertical_interior_blind'"
),
"blind": "device type 'blind' was renamed: use 'vertical_interior_blind' instead",
"venetian_blind": "device type 'venetian_blind' was renamed: use 'interior_venetian_blind' instead",
"awning": "device type 'awning' was renamed: use 'vertical_exterior_awning' instead",
"dual_shutter": "device type 'dual_shutter' was renamed: use 'dual_roller_shutter' instead",
"external_venetian_blind": (
"device type 'external_venetian_blind' was renamed: use 'exterior_venetian_blind' instead"
),
}

Definition at line 225 of file hub_validators.py.

◆ SPI_RADIO_TYPES

home_io_control.hub_validators.SPI_RADIO_TYPES = frozenset({"sx1276", "sx1262", "lr1121"})

Definition at line 50 of file hub_validators.py.

◆ TCXO_VOLTAGE_OPTIONS

dict home_io_control.hub_validators.TCXO_VOLTAGE_OPTIONS
Initial value:
= {
"1_6V": 0x00,
"1_7V": 0x01,
"1_8V": 0x02,
"2_2V": 0x03,
"2_4V": 0x04,
"2_7V": 0x05,
"3_0V": 0x06,
"3_3V": 0x07,
"NONE": 0xFF,
}