Home IO Control
ESPHome add-on for IO-Homecontrol devices
|
What the hub has read from one heater so far. More...
#include <proto_heating.h>
Public Member Functions | |
| bool | store (HeatingFunction fn, float value) |
| Fold one decoded register value into the readings. | |
| bool | has (HeatingFunction fn) const |
| Has this register been read yet? | |
Public Attributes | |
| float | room_temperature_c {NAN} |
| Measured room temperature; NaN until read or on a sensor fault. | |
| float | setpoint_c {NAN} |
| Comfort setpoint as the heater holds it; NaN until read. | |
| float | max_setpoint_c {NAN} |
| Highest setpoint the heater accepts; NaN until read. | |
| int16_t | mode {-1} |
| HeatingMode value; -1 until read. | |
| int16_t | regulator {-1} |
| HeatingRegulatorState value; -1 until read. | |
| int16_t | window_open {-1} |
| 0 closed / 1 open; -1 until read. | |
| int16_t | open_window_detection {-1} |
| 1 detection on / 0 off; -1 until read. | |
| int16_t | level {-1} |
| Low byte of the main parameter of a heater commanded with a prefixed value: a heating level, or a setpoint alias. | |
| int32_t | main_parameter {-1} |
| The raw current main parameter of a heater commanded with an EXECUTE (a temperature, an alias or a level); -1 until a status reply carried one. | |
What the hub has read from one heater so far.
Every field starts as "never read" (NaN, or -1 for the byte registers). Only a decoded reply changes a field, so what an entity shows from here is observed, never predicted.
Definition at line 178 of file proto_heating.h.
|
nodiscard |
Has this register been read yet?
| fn | Register. |
Definition at line 279 of file proto_heating.cpp.
| bool esphome::home_io_control::HeatingReadings::store | ( | HeatingFunction | fn, |
| float | value ) |
Fold one decoded register value into the readings.
| fn | Register the value was read from. |
| value | Value as returned by decode_heating_reply(). |
Definition at line 248 of file proto_heating.cpp.
| int16_t esphome::home_io_control::HeatingReadings::level {-1} |
Low byte of the main parameter of a heater commanded with a prefixed value: a heating level, or a setpoint alias.
-1 until a status reply carried one, and again after a reply that carried a plain temperature. Set by the hub's status path, not by store().
Definition at line 186 of file proto_heating.h.
| int32_t esphome::home_io_control::HeatingReadings::main_parameter {-1} |
The raw current main parameter of a heater commanded with an EXECUTE (a temperature, an alias or a level); -1 until a status reply carried one.
Set by the hub's status path, not by store().
Definition at line 190 of file proto_heating.h.
| float esphome::home_io_control::HeatingReadings::max_setpoint_c {NAN} |
Highest setpoint the heater accepts; NaN until read.
Definition at line 181 of file proto_heating.h.
| int16_t esphome::home_io_control::HeatingReadings::mode {-1} |
HeatingMode value; -1 until read.
Definition at line 182 of file proto_heating.h.
| int16_t esphome::home_io_control::HeatingReadings::open_window_detection {-1} |
1 detection on / 0 off; -1 until read.
Definition at line 185 of file proto_heating.h.
| int16_t esphome::home_io_control::HeatingReadings::regulator {-1} |
HeatingRegulatorState value; -1 until read.
Definition at line 183 of file proto_heating.h.
| float esphome::home_io_control::HeatingReadings::room_temperature_c {NAN} |
Measured room temperature; NaN until read or on a sensor fault.
Definition at line 179 of file proto_heating.h.
| float esphome::home_io_control::HeatingReadings::setpoint_c {NAN} |
Comfort setpoint as the heater holds it; NaN until read.
Definition at line 180 of file proto_heating.h.
| int16_t esphome::home_io_control::HeatingReadings::window_open {-1} |
0 closed / 1 open; -1 until read.
Definition at line 184 of file proto_heating.h.